Sensor Select
This function lets you select the status (ON or OFF)
and installation type (NC for Normally Closed or NO
for Normally Open) of any rain or moisture sensor
connected to your PAR+ES�
From the “Relay-Board Test” screen, press the
1.
SYSTEM INFORMATION button� The “Sensor
Select” screen appears� (If the display reads
“Relay-Board Test Found 1�2����” press the SYSTEM
INFORMATION button TWICE to access the
“Sensor Select” screen�)
Line 2 displays the sensor status (ON or OFF)�
2.
Press the UP / DOWN arrows to select the desired
status� If the sensor status is OFF (the default),
the controller will ignore all sensor input� Sensor
status ON means the controller will respond to
sensor input�
NOTE:
!
If the rain sensor activates, the
controller will cancel any schedule(s) in
progress , and the Clock Status screen will
flash a “Sensor Active” message�
When sensor status is ON, line 2 will also display
3.
the sensor installation type (“NC” for normally
closed or “NO” for normally open)�
Press the RIGHT / LEFT arrows to move to the
4.
sensor type� Press the UP / DOWN arrows to select
the proper sensor installation type (NC or NO) for
your system�
Internal Self-Test
This function tests the controller’s internal memory,
hardware, and power-up display�
From the “Sensor Select” screen, press the SYSTEM
1.
INFORMATION button to display the “Self Test”
screen�
The display reads “Push ‘START’ to begin�” Press
2.
the START / ADVANCE button to begin the self-
test� The controller will automatically run through
the test procedure and show any failures in the
display� Then the controller will return to Clock
Status mode�
Note any failure message and contact your Rain
Bird distributor for assistance�