PAR+ES Operation Manual 25
DISPLAY
CONTROL
PROGRAMMING CONTROLS OPERATING CONTROLS
STATION RUN TIMES
START TIMES
START DAYS
WATER BUDGET
WEEKDAY / CYCLE
CLOCK STATUS
SCHEDULE MONITOR
MULTI-MANUAL
SET CLOCK
SYSTEM INFORMATION
COPY STORE
COPY PASTE
PROGRAMMING CONTROLS OPERATING CONTROLS
STATION RUN TIMES
START TIMES
START DAYS
WATER BUDGET
WEEKDAY / CYCLE
CLOCK STATUS
SCHEDULE MONITOR
MULTI-MANUAL
SET CLOCK
SYSTEM INFORMATION
COPY STORE
COPY PASTE
CONTROL MODE
START / ADVANCE
DISPLAY
CONTROL
OFF MANUAL LOCAL MAXI
CANCEL / CLEAR
DISPLAY
CONTROL
Sensor Select
This function lets you select the status (ON or OFF)
and installation type (NC for Normally Closed or NO
for Normally Open) of any rain or moisture sensor
connected to your PAR+ES�
From the “Relay-Board Test” screen, press the
1.
SYSTEM INFORMATION button� The “Sensor
Select screen appears� (If the display reads
“Relay-Board Test Found 1�2���� press the SYSTEM
INFORMATION button TWICE to access the
“Sensor Select” screen�)
Line 2 displays the sensor status (ON or OFF)�
2.
Press the UP / DOWN arrows to select the desired
status� If the sensor status is OFF (the default),
the controller will ignore all sensor input� Sensor
status ON means the controller will respond to
sensor input�
NOTE:
!
If the rain sensor activates, the
controller will cancel any schedule(s) in
progress , and the Clock Status screen will
flash a “Sensor Active message�
When sensor status is ON, line 2 will also display
3.
the sensor installation type (“NC for normally
closed or “NO for normally open)�
Press the RIGHT / LEFT arrows to move to the
4.
sensor type� Press the UP / DOWN arrows to select
the proper sensor installation type (NC or NO) for
your system�
Internal Self-Test
This function tests the controller’s internal memory,
hardware, and power-up display
From the “Sensor Select screen, press the SYSTEM
1.
INFORMATION button to display the “Self Test
screen�
The display reads “Push ‘START to begin� Press
2.
the START / ADVANCE button to begin the self-
test� The controller will automatically run through
the test procedure and show any failures in the
displayThen the controller will return to Clock
Status mode�
Note any failure message and contact your Rain
Bird distributor for assistance�
Sensor Select
Stat: OFF
Relay-Board Test
...Push Start...
Sensor Select
Stat: ON Type:NC
1
2
1
4
3
2
635777 Rev B (PAR+ES operations manual (1of2 ENG)) source.indd 25 12/20/2007 8:40:21 AM