• ET Pulse with Weather Interrupt:
- Output Method = ET Pulse with Interrupt
- Rain Source = As needed
- Pulse per Minute = 10
- ET Pulse Duration = 0.2 seconds
- Weather Interrupt = Wind, Temperature and Rain as needed
Maxicom
2
System Software Setup
ET and Rain Pulse
CCU Properties
• CCU Two-Wire / Pulse Decoder:
- ET Pulse input: Select Channel Properties on an unused channel.
Device Category = Sensor/Decoder
Device Type = Site ET Collector (SETC)
Device Name = ET Manager
In/Pulse = 0.01 (default)
- Rain Pulse input: Select Channel Properties on an unused channel.
Device Category = Sensor/Decoder
Device Type = Site Rain Collector (SRC)
Device Name = Rain Can
In/Pulse = 0.01 (default)
• ESP-SITE-Satellite or ESP-SAT Link-Radio Satellite:
- ET Pulse input: Select Channel Properties on a Satellite channel.
Device Category = Satellite with Sensor Input(s)
Select Sensor Input A or B Properties
Device Type = ET Gauge
Device Name = ET Manager
In/Pulse = 0.01 (default)
- Rain Pulse input: Select Channel Properties on a Satellite channel.
Device Category = Satellite with Sensor Input(s)
Select Sensor Input A or B Properties
Device Type Site Rain Collector (SRC)
Device Name = ET Manager
In/Pulse = 0.01 (default)
- Note: Both ET Pulse and Rain Pulse inputs should not be used on the same CCU Channel.